Flow Cytometry Controls




StatusFlow Lo Flow Cytometry Control

StatusFlowLO is designed to team with StatusFlow to provide a two-level whole blood reference control for monitoring low CD3+/CD4+cell counts. Assay values are reported as a percent of total lymphocytes and as the number of cells for CD3+, CD3+/CD4+, CD3+/CD8+, CD19+, and CD3-/CD16+56+. The CD3+/CD4+cell count is less than 200 cells/(u)L. StatusFlowLO has a closed vial stability of 45 days with an open vial stability of 9 thermal cycles.
45-day closed vial stability; 1 QC month
9 thermal cycles open vial stability
Packaged in 2.5mL pierceable Hemogard tubes
Assayed for BD Biosciences FACS series, BECKMAN COULTER Elite, Epics, Profile and Epics XL, and Manual Methods

StatusFlow(R) Flow Cytometry Control

StatusFlow is a stable preparation of human peripheral leukocytes and erythrocytes designed for use as a control in immunopheno-typing when evaluating RBC lysis, antibody reactivity, instrument set-up, and instrument performance by flow cytometry. Assay values are reported as a percent of total lymphocytes and as the number of cells for the following phenotypes: CD3+, CD3+/CD4+, CD3+/CD8+, CD19+, CD3-/CD16+56+, CD20+, CD2+, and HLA-DR+. Target values (for research use only) are also provided for the following CD markers: kappa, lambda, CD8+/CD38+, CD33+/CD14+, CD7+/CD3+, CD5+, CD22+/CD3-, and CD13+. Target values for CD45 and CD14, which are intended for gating purposes only, are also included. StatusFlow has a closed vial stability of 45 days with an open vial stability of 9 thermal cycles.
45-day closed vial stability; 1 QC month
9 thermal cycles open vial stability
Packaged in 2.5mL pierceable Hemogard tubes
Assayed for BD Biosciences FACS series, BECKMAN COULTER Elite, Epics, Profile and Epics XL, and Manual Methods

StatusFlow Pro Flow Cytometry Control

StatusFlowPRO contains human stem cells and can be used with most flow cytometry methods for identifying CD34+cells. StatusFlowPRO offers two clinically relevant levels of CD34+ cells. Target values for the Low Level CD34 are approximately 10 cells/uL. Target values for the High Level CD34 are approximately 35 cells/uL. StatusflowPRO facilitates the evaluation of CD34+ gating strategy, evaluation of the CD34 antibody clone selection, lysing reagents and data analysis. StatusFlowPRO has a closed vial stability of 45 days with an open vial stability of 9 thermal cycles.
45-day closed vial stability; 1 QC month
9 thermal cycles open vial stability
Packaged in 1.5mL pierceable Hemogard tubes
Assayed for BD Biosciences FACS series, BECKMAN COULTER Elite, Epics, Profile and Epics XL, and Manual Methods